Products-Industrial temperature sensor-MI metal sheathed thermocouples-Termocouple tolerance and applicable standards
Thermocouple Tolerance and Applicable Standards
|
JIS C1605
|
|
IEC 584-2
|
ASTM E230
|
Temp
Range
|
Class
|
Tolerance
℃
|
Temp
Range
|
Class
|
Tolerance
℃
|
Temp
Range
|
Class
|
Tolerance
℃
|
SN SK
|
-40℃~+375℃
|
1
|
±1.5
|
N K
|
-40℃~+375℃
|
1
|
±1.5
|
+0℃~+1260℃
|
普通级
|
±2.2℃~
±0.75%
|
+375℃~+1000℃
|
±0.004 |t|
|
+375℃~+1000℃
|
±0.004 |t|
|
-40℃~+333℃
|
2
|
±0.0075 |t|
|
-40℃~+333℃
|
2
|
±0.0075 |t|
|
精密级
|
±1.1℃~
±0.4%
|
+333℃~+1200℃
|
±2.5
|
+333℃~+1200℃
|
±2.5
|
-167℃~+40℃
|
3
|
±0.015 |t|
|
-167℃~+40℃
|
3
|
±0.015 |t|
|
-200℃~0℃
|
普通级
|
±2.2℃~
±2%
|
-200℃~-167℃
|
±2.5
|
-200℃~-167℃
|
±2.5
|
SE
|
-40℃~
+375℃
|
1
|
±1.5
|
E
|
-40℃~+375℃
|
1
|
±1.5
|
+0℃~+870℃
|
普通级
|
±1.7℃~
±0.5%
|
+375℃~+800℃
|
±0.004 |t|
|
+375℃~+800℃
|
±0.004 |t|
|
-40℃~+333℃
|
2
|
±0.0075 |t|
|
-40℃~+333℃
|
2
|
±0.0075 |t|
|
精密级
|
±1℃~
±0.4%
|
+333℃~+900℃
|
±2.5
|
+333℃~+900℃
|
±2.5
|
-167℃~+40℃
|
3
|
±0.015 |t|
|
-167℃~+40℃
|
3
|
±0.015 |t|
|
-200℃~0℃
|
普通级
|
±1.7℃~
±1%
|
-200℃~-167℃
|
±2.5
|
-200℃~-167℃
|
±2.5
|
SJ
|
-40℃~+375℃
|
1
|
±1.5
|
J
|
-40℃~+375℃
|
1
|
±1.5
|
+0℃~+760℃
|
普通级
|
±2.2℃~
±0.75%
|
+375℃~+750℃
|
±0.004 |t|
|
+375℃~+750℃
|
±0.004 |t|
|
-40℃~+333℃
|
2
|
±0.0075 |t|
|
-40℃~+333℃
|
2
|
±0.0075 |t|
|
精密级
|
±1.1℃~
±0.4%
|
+333℃~+750℃
|
±2.5
|
+333℃~+750℃
|
±2.5
|
ST
|
-40℃~+125℃
|
1
|
±0.5
|
T
|
-40℃~+125℃
|
1
|
±0.5
|
+0℃~+370℃
|
普通级
|
±1℃~
±0.75%
|
+125℃~+350℃
|
±0.004 |t|
|
+125℃~+350℃
|
±0.004 |t|
|
-40℃~+133℃
|
2
|
±0.0075 |t|
|
-40℃~+133℃
|
2
|
±0.0075 |t|
|
精密级
|
±0.5℃~
±0.4%
|
+133℃~+350℃
|
±1.0
|
+133℃~+350℃
|
±1.0
|
-67℃~+40℃
|
3
|
±0.015 |t|
|
67℃~+40℃
|
3
|
±0.015 |t|
|
-200℃~
0℃
|
普通级
|
±1℃~
±1.5%
|
-200℃~-67℃
|
±1.0
|
-200℃~-67℃
|
±1.0
|
(1) Tolerance is referred to as the maximum allowable deviation between measuring junction temperature and the temperature derived from the emf table.
(2) ASTM tolerance is ℃ or % value for the measured temperature, whichever is greater.
(3) |t| means measuring temperature indicated with the temperature (℃) having no connection with the positive or negative mark.
|