Products-Industrial temperature sensor-MI metal sheathed thermocouples-Inspection standards
Inspection Standard
Dimensional
Inspection
|
Sheath OD
|
Φ0.5~Φ4.8 mm ±0.05 mm
Φ6.0~Φ8.0 mm ±0.10 mm
|
Length of Sheath
|
<150 mm ±2.0 mm
≥150 mm ±1.5%
Spring type ±3.0 mm
The Maximum length is 1 meter.The longer lengths than 1 meter tobe discussed later.
|
Nipple length
|
±3 mm
|
Compensating cable length
|
<1000 mm ±15 mm
≥1000 mm ±1.5%
|
E.M.F. Test
|
T Thermocouple
|
100℃ Boiling point of water
|
N, K, E, J Thermocouple
|
300℃ Comparison with Reference
Thermocouple unsing 300℃ Niter Bath
|
Insulation
Resistance
Test
|
The resistance between the wire and the sheath is measured at room temperature. (However this test is not performed for the grounded junction type.)
|
|
|
Sheath OD (mm)
|
Characteristics
|
|
Φ0.15 ≤ OD < Φ0.25
|
5 MΩ / 25 V DC
|
|
Φ0.25 ≤ OD < Φ0.5
|
5 MΩ / 50 V DC
|
|
Φ0.5 ≤ OD < Φ2.0
|
20 MΩ / 100 V DC
|
|
OD > Φ2.0
|
100 MΩ / 500 V DC
|
Inspection Table Inspection Certificate is attached to the product.Whenever the inspection results are especially required,please so advise.
|