ProductsIndustrial temperature sensorAssembling type thermocouplesTolerance and applicable standards

Thermocouple Tolerance and Applicable Standards 

JIS C1602

IEC 584-2

ASTM E230

Temp range

Class

Tolerance

Class

Tolerance

Temp range

Class

Tolerance

B

600℃~1700

2

±0.0025|t|

2

±0.0025|t|

870℃~1700

STD

±0.5 %

600℃~800

3

±4

3

±4

800℃~1700

±0.005|t|

±0.005|t|

R S

0℃~1100

1

±1

1

±1

0℃~1450

STD

±1.5
±0.25%

0℃~600

2

±1.5

2

±1.5

SP

±0.6    ±0.1%

600℃~1600

±0.0025|t|

±0.0025|t|

N K

-40℃~+375

1

±1.5

1

±1.5

0℃~+1260

STD

±2.2    ±0.75%

+375℃~+1000

±0.004 |t|

±0.004 |t|

-40~+333

2

±2.5

2

±2.5

SP

±1.1       ±0.4%

+333℃~+1200

±0.0075|t|

±0.0075|t|

-167~+40

3

±2.5

3

±2.5

-200℃~0

STD

±2.2    ±2%

-200~-167

±0.015|t|

±0.015|t|

E

-40~+375

1

±1.5

1

±1.5

0℃~+870

STD

±1.7    ±0.5%

+375℃~+800

±0.004 |t|

±0.004 |t|

-40~+333

2

±2.5

2

±2.5

SP

±1          ±0.4%

+333℃~+900

±0.0075 |t|

±0.0075 |t|

-167℃~+40

3

±2.5

3

±2.5

-200℃~0

STD

±1.7    ±1%

-200℃~-167

±0.015|t|

±0.015|t|

J

-40℃~+375

1

±1.5

1

±1.5

0℃~+760

STD

±2.2       ±0.75%

+375℃~+750

±0.004 |t|

±0.004 |t|

-40℃~+333

2

±2.5

2

±2.5

SP

±1.1    ±0.4%

+333℃~+750

±0.0075 |t|

±0.0075 |t|

T

-40+125

1

±0.5

1

±0.5

0℃~+370

STD

±1 ±0.75%

+125+350

±0.004 |t|

±0.004 |t|

-40+133

2

±1.0

2

±1.0

SP

±0.5±0.4%

+133+350

±0.0075 |t|

±0.0075 |t|

-67+40

3

±1.0

3

±1.0

-200℃~0

STD

±1±1.5%

-200-67

±0.015|t|

±0.015|t|

(1) Tolerance is referred to as the maximum allowable deviation between measudng junction temperature and the temperature dedved from the emf table

(2) ASTM tolerance is or value for the measured temperature. whichever is greater

(3) ItI means measuring temperature indicated with the temperature () having no connection with the positive or negative mark

 


 

 
在线客服