Inspection Standard of RTDs
Appearance and Construction
Inspect
|
Terminal head, welded and/or soldered areas, screwed areas, name plate and other parts shall be inspected with naked eyes. Dye penetrating check or airtight test shall be performed on welded and/or soldered areas, if required.
|
Dimensional
Inspection
|
OD of protection tube
|
Φ3.0¡«Φ5.0 mm ±0.05 mm
Φ6.0¡«Φ6.4 mm ±0.06 mm
Φ8¡«Φ22mm ±1%
|
|
Length of protection tube
|
<150 mm ± 2.0 mm
≥150 mm ± 1.5%
|
|
Nipple length
|
±3 mm
|
|
Other parts
|
Dimensions of the parts specified on the drawing shall be measured with a measuring tool. Unless otherwise specified, the measurement shall be performed in accordance with IEC.
|
Nominal
resistance test
|
Nominal resistance value
|
0¡æ Icing point of water
|
Insulation
Resistance test
|
The resistance between the conductor and the sheath is measured at room temperature.
|
|
OD of protection tube
|
Characteristics
|
|
Φ3.0¡«Φ22
|
100 MΩ / 100 VDC
|
Qualified Certificate
|
Inspection Certificate is attached to the product. Whenever the inspection results are especially required, please so advise.
|
|