Products-Industrial temperature sensor-Metal protection tubes and thermowells-Inspection standards
Inspection Standard
Appearance
Inspection
|
Flange
|
To be checked per Flange Standards
|
|
Length and Outside/
Inside Diameters
|
Dimensions of the pars specified on drawings shall be measured with a measuring tool, unless otherwise specified, the measurement shall be performed in accordance with JIS B0405.
|
|
Thread
|
To be checked with thread gauge
|
Material Inspection
|
Inspection shall be performed by Material Certificate supplied by manufacturer and applicable standards, if specified.
|
Airtight
Inspection
|
In order to check air-tightness of protection tube or thermowell, airtight inspection shall be performed with specified pressure if specified.
|
Hydraulic
inspection
|
In order to check hydraulic of protection tube or thermowell, hydraulic inspection shall be performed with specified pressure if specified.
|
X-ray inspection
|
All of the drilled thermowell with longer length than 750 mm shall be inspected on the wall thickness including that of the tip. The others shall be inspected if specified.
|
Thermowell length
|
Tolerance of thermowell
wall thickness
|
Tolerance of tip wall thickness
|
<500 mm
|
±0.3 mm
|
+0.5 mm
0
|
≥500 mm
|
±0.5 mm
|
Dye Penetrating
Inspection
|
The welded areas shall be inspected if specified.
|
|